【24h】

Impact of time interval alignment on data quality in electricity grids

机译:时间间隔对齐对电网数据质量的影响

获取原文

摘要

Measurements of parameters in electricity grids are frequently average values over some time interval. In scenarios of distributed measurements such as in distribution grids, offsets of local clocks can result in the averaging interval being misaligned. This paper investigates the properties of the so-called time alignment error of such measurands that is caused by shifts of the averaging interval. A Markov model is derived that allows for numerically calculating the expected value and other distribution properties of this error. Actual consumption measurements of an office building are used to study the behavior of this time alignment error, and to compare the results from the trace with numerical results and simulations from a fitted Markov model. For increasing averaging interval offset, the time alignment error approaches a normal distribution, whose parameters can be calculated or approximated from the Markov model.
机译:电网参数的测量通常是某个时间间隔内的平均值。在分布式测量的场景中(例如在分布式网格中),本地时钟的偏移会导致平均间隔未对齐。本文研究了由于平均间隔的偏移而导致的这种被测时间所谓的时间对准误差的性质。得出了一个马尔可夫模型,该模型允许通过数值计算此误差的期望值和其他分布特性。办公楼的实际消耗量测量用于研究此时间校准误差的行为,并将跟踪的结果与数值结果和拟合的Markov模型的模拟结果进行比较。为了增加平均间隔偏移,时间对准误差接近正态分布,其参数可以从马尔可夫模型计算或近似。