首页> 外文会议>ICEMS2007;International conference on electrical machines and systems >The AC Breakdown Voltage Measurement of an Evaporative Coolant under Two-phase-flow Condition and Its Statistical Analysis with Weibull Distribution and Normal Distribution
【24h】

The AC Breakdown Voltage Measurement of an Evaporative Coolant under Two-phase-flow Condition and Its Statistical Analysis with Weibull Distribution and Normal Distribution

机译:两相流条件下蒸发冷却剂的交流击穿电压测量及其Weibull分布和正态分布的统计分析

获取原文

摘要

As some fluorocarbons have the nonflammability and high electrical strength, they could be used not only as coolant, but also as insulating materials. In order to obtain the AC breakdown voltage of some fluorocarbons under two-phaseflow condition, special experimental equipment was designed and fabricated. Using a plane-plane electrode with a gap length of 3 mm, the test was carried out and the result was analyzed statistically. The analysis demonstrated that both the Weibull and Normal distribution match the result quite well. The more the data samples are, the better the statistical distributions will match. Under the condition of a small quantity of samples, it’s better to prefer Normal distribution because of the less error it has. Meanwhile, the Weibull distribution matches the sample better under the circumstances of a large quantity of samples.
机译:由于某些碳氟化合物具有不燃性和高电强度,因此它们不仅可以用作冷却剂,而且可以用作绝缘材料。为了获得两相流动条件下某些碳氟化合物的交流击穿电压,设计并制造了专用的实验设备。使用间隙长度为3 mm的平面电极进行测试,并对结果进行统计分析。分析表明,威布尔分布和正态分布都很好地匹配了结果。数据样本越多,统计分布将越匹配。在少量样本的情况下,最好选择正态分布,因为它的误差较小。同时,在大量样本的情况下,威布尔分布与样本的匹配更好。