首页> 外文会议>Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON), 2012 9th International Conference on >Protective device placement for reliability improvement by considering anti-islanding protection of PV generation system
【24h】

Protective device placement for reliability improvement by considering anti-islanding protection of PV generation system

机译:通过考虑光伏发电系统的防孤岛保护来放置保护装置以提高可靠性

获取原文
获取原文并翻译 | 示例

摘要

At present, the solar energy is a highly potential alternative for solving the energy crisis and improving system quality. On the other hand, the penetration of PVGS may cause an islanding problem. This paper derives Non Detection Zone (NDZ) of Over/Under voltage and Over/Under frequency method in order to increase accuracy for islanding prevention. In addition to safety issue, this paper proposes the protective device placement for system reliability improvement by using Genetic Algorithm (GA) optimization. The optimization also takes account of islanding prevention as constraint. The proposed method is brought to apply with Tasine 34-bus distribution system, and the simulation results are satisfactory.
机译:目前,太阳能是解决能源危机和提高系统质量的极具潜力的替代品。另一方面,PVGS的渗透可能会引起孤岛问题。为了提高防止孤岛的准确性,本文推导了过压/欠压和频率过压/欠频的非检测区(NDZ)。除了安全问题,本文还提出了使用遗传算法(GA)优化来提高系统可靠性的保护装置布置。该优化还考虑了将防孤岛作为约束条件。将该方法应用于Tasine 34客车配电系统,仿真结果令人满意。