首页> 外文会议>Developments in X-Ray Tomography IV >A robust procedure for determination of center of rotation in tomography
【24h】

A robust procedure for determination of center of rotation in tomography

机译:确定断层扫描旋转中心的可靠程序

获取原文
获取原文并翻译 | 示例

摘要

Performing computed assisted tomography (CAT) requires a perfect centering of the rotation axis with the center of the detector. This requirement is sometimes hard to obtain. Thus, a post acquisition centering correction of the acquired data is mandatory. Several correction techniques can be found in the literature. However, all of them are not completely reliable when the measure is not performed in perfect experimental condition. As matter of fact, researcher use to fit the center of rotation by a post measure visual inspection of the projections. This approach is not practical at high-throughput tomography system where hundreds of samples a day can be easily measured [1], moreover, the visual approach does not always give the best centering. In this paper we report a new centering technique that is more robust when the quality of the acquired data is poor due to low contrast or noisy acquisition.
机译:执行计算机辅助断层扫描(CAT)要求旋转轴与检测器中心完美对准中心。有时很难达到这一要求。因此,必须对采集到的数据进行采集后居中校正。在文献中可以找到几种校正技术。但是,如果未在理想的实验条件下执行该措施,则所有这些方法都不完全可靠。实际上,研究人员通常通过对投影的后测量目测来拟合旋转中心。这种方法在高通量层析成像系统中不可行,该系统每天可以轻松测量数百个样品[1],此外,视觉方法并不总是能提供最佳的居中效果。在本文中,我们报告了一种新的居中技术,当由于低对比度或嘈杂的采集而导致采集的数据质量较差时,该技术将更加强大。