首页> 外文会议>Conference on High-Energy Detectors in Astronomy; 20040622-20040623; Glasgow; GB >A cryogenic imaging X-ray spectrometer for XEUS read out by frequency-division SQUID multiplexers
【24h】

A cryogenic imaging X-ray spectrometer for XEUS read out by frequency-division SQUID multiplexers

机译:通过频分SQUID多路复用器读出的XEUS低温成像X射线光谱仪

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

A micro-calorimeter array with superconducting transition-edge sensors read out by a SQUID-based frequency-domain multiplexer is under development for the X-ray imaging spectrometer on board ESA's X-ray Evolving Universe Spectroscopy (XEUS) mission. The XEUS requirements are 2 and 5 eV FWHM energy resolution for 2 and 7 keV X-rays, respectively. An array of 32 x 32 pixels with 250 micron square pixels is envisaged. SRON and MESA~+ have developed 5x5 imaging micro-calorimeter prototype arrays along a bulk micromachining and a surface micromachining route. The present state of array design and development with emphasis on pixel-to-pixel performance measurements of thermal and Ⅰ-Ⅴ characteristics, sensor noise and energy resolution are presented. SRON and VTT are developing frequency-domain multiplexing with SQUID current amplifiers to read out the 32 x 32 array. The concept for the frequency division multiplexing read-out will be presented and its performance characteristics discussed. Recent results of sensor operation under AC-bias (500 kHz) are presented.
机译:ESA的X射线演化宇宙光谱(XEUS)任务中的X射线成像光谱仪正在开发一种具有基于SQUID的频域多路复用器读取的具有超导过渡边缘传感器的微热量计阵列。 XEUS要求分别针对2和7 keV X射线提供2和5 eV FWHM能量分辨率。设想了具有250微米见方像素的32 x 32像素阵列。 SRON和MESA〜+已沿着整体微加工和表面微加工路线开发了5x5成像微热量计原型阵列。介绍了阵列设计和开发的当前状态,重点介绍了像素和像素的热和Ⅰ-Ⅴ特性,传感器噪声和能量分辨率的性能测量。 SRON和VTT正在与SQUID电流放大器一起开发频域多路复用,以读出32 x 32阵列。将介绍频分复用读出的概念,并讨论其性能特征。介绍了传感器在AC偏置(500 kHz)下工作的最新结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号