X-ray microtomography was applied for in-situ study of void coalescence during high-temperature creep of a brass alloy. Using image correlation techniques the movement of single slices and cavities connected to these images were monitored during deformation. Coalescence of voids was detected using ancestors analysis and independently checked with a geometrical parameter describing the distorted cavity shape. The analysis of in situ results suggests the existence of a critical volume fraction, as well as critical value of the ligament size between cavities at the onset of coalescence. The maximum number of primary coalescence events takes place in the tertiary stage of creep.
机译:X射线显微照相技术用于黄铜合金高温蠕变过程中空隙聚结的原位研究。使用图像相关技术,在变形期间监视与这些图像相连的单个切片和空腔的运动。使用祖先分析检测空隙的聚结,并使用描述变形空腔形状的几何参数独立检查。对原位结果的分析表明,在合并开始时,存在临界体积分数以及腔之间韧带大小的临界值。一次合并事件的最大数量发生在蠕变的第三阶段。