首页> 外文会议>Biomedical engineering >IMPROVEMENT OF THE ACTIMETRY AGREEMENT AMONG SITES BY PROPER CHOICE OF SIGNAL PROCESSING STAGES
【24h】

IMPROVEMENT OF THE ACTIMETRY AGREEMENT AMONG SITES BY PROPER CHOICE OF SIGNAL PROCESSING STAGES

机译:通过适当选择信号处理阶段来改进站点之间的许可协议

获取原文
获取原文并翻译 | 示例

摘要

Physical activity (PA) has been identified as a key health indicator and has been assessed in multiple studies as the study of cardiovascular diseases, diabetes mellitus, obesity and psychological conditions. For this reason the use of accelerometers to quantify PA is widely accepted in either clinical/laboratory settings as well as in free-living environments. The use of accelerometers in the measurement of PA is a relatively new technique and, therefore, has been not standardized. The aim of this work is to study the influence of signal processing stages in the estimation of PA while measuring simultaneously in three different sites to provide robust indicators of activity in front of changes in site measurement. With our measurement we show that a proper choice of signal processing steps can improve the agreement among activity indices measured from different sites on the same individual. The results also show that the most suited index is the time above threshold. In this case, the best combination of axes is by applying the quadratic mean, the best filtering of axes is using a cut-off frequency of around 1.5 Hz and a threshold to compute the index of 0.04 g.
机译:身体活动(PA)已被确定为关键健康指标,并且在多项研究中都被评估为对心血管疾病,糖尿病,肥胖症和心理状况的研究。因此,在临床/实验室环境以及自由生活的环境中,使用加速度计来量化PA的方法已被广泛接受。在PA测量中使用加速度计是一种相对较新的技术,因此尚未标准化。这项工作的目的是研究信号处理阶段对功率放大器估计的影响,同时在三个不同的站点同时进行测量,以在站点测量变化之前提供活动的可靠指标。通过我们的测量,我们表明,正确选择信号处理步骤可以提高从同一个人的不同位置测量的活动指数之间的一致性。结果还表明,最合适的指标是高于阈值的时间。在这种情况下,轴的最佳组合是应用二次均值,轴的最佳滤波是使用约1.5 Hz的截止频率和阈值来计算指标0.04 g。

著录项

  • 来源
    《Biomedical engineering》|2012年|371-375|共5页
  • 会议地点 Innsbruck(AT)
  • 作者单位

    Group of Biomedical and Electronic Instrumentation, Department of Electronic Engineering, Technical University of Catalonia (UPC), C/Jordi Girona 1-3, 08034, Barcelona, Spain;

    Group of Biomedical and Electronic Instrumentation, Department of Electronic Engineering, Technical University of Catalonia (UPC), C/Jordi Girona 1-3, 08034, Barcelona, Spain;

    Group of Biomedical and Electronic Instrumentation, Department of Electronic Engineering, Technical University of Catalonia (UPC), C/Jordi Girona 1-3, 08034, Barcelona, Spain;

    Group of Biomedical and Electronic Instrumentation, Department of Electronic Engineering, Technical University of Catalonia (UPC), C/Jordi Girona 1-3, 08034, Barcelona, Spain;

    Group of Biomedical and Electronic Instrumentation, Department of Electronic Engineering, Technical University of Catalonia (UPC), C/Jordi Girona 1-3, 08034, Barcelona, Spain;

    Group of Biomedical and Electronic Instrumentation, Department of Electronic Engineering, Technical University of Catalonia (UPC), C/Jordi Girona 1-3, 08034, Barcelona, Spain;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    measurement and instrumentation; biomedical signal processing; smartphone actimetry; wrist actimetry;

    机译:测量和仪器;生物医学信号处理;智能手机活性计腕部活动度;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号