This paper reports and dicusses the results and experiences of CWT mode operation in 300MW once-through boiler unit, in which the low pressure heater tube is made of copper alloy. The results show that CWT technique can e-liminate the scaling problem in flow throttle control valves of feedwater pump, prevent the increase in boiler pressure drop, economize the dynamic spend of feedwater pump, reduce Fe content in water-steam cycle circuit and so on- In this test and operation, the control criterion of water quality under CWT operation for actual unit has been defined.
机译:本文报道并讨论了300MW直流锅炉机组(其中低压加热器管由铜合金制成)以CWT模式运行的结果和经验。结果表明,CWT技术可以消除给水泵节流控制阀中的结垢问题,防止锅炉压降的增加,节约给水泵的动态费用,减少水蒸汽循环回路中的铁含量等。 -在此测试和操作中,已定义了实际机组在CWT操作下的水质控制标准。