【24h】

HPLC Method Research of Picoplatin-a New Platinum Anti-cancer Drug and Its Impurities

机译:新型铂抗癌药物吡铂的HPLC方法研究及其杂质

获取原文
获取原文并翻译 | 示例

摘要

Purpose: To establish a HPLC testing method of the content of bulk picoplatin and its impurities. Method: the separation was perform on a C18 column(4.6 mmx250 mm, 5 urn) with potassium dihydrogen phosphate-aceton-itrile as the mobile phase at a flow rate of 1.0 mL/min. The detecting wavelength was set at 210 nm, and the column temperature was set at 30℃. Result: in the method validation, the linear relationship modulus of picoplatin is 0.9999, the systemic precision is 0.44%, the method precision is 0.74%, the average recovery rate is 99.62%, the LOD and LOQ of picoplatin is 0.2 ng and 1.0 ng. The average resolution of picoplatin and its impurities is more than 2. Conclusion: The established method is good specificity, high sensitivity, and good repeatability which could provide scientific evidence for the quality control of picoplatin and its impurities.
机译:目的:建立散装吡铂及其杂质含量的HPLC检测方法。方法:在C18色谱柱(4.6 mmx250 mm,5毫米)上,以磷酸二氢钾-丙酮-腈为流动相,以1.0 mL / min的流速进行分离。检测波长设定为210nm,柱温设定为30℃。结果:在方法验证中,吡铂的线性关系模量为0.9999,系统精度为0.44%,方法精度为0.74%,平均回收率为99.62%,吡铂的LOD和LOQ为0.2 ng和1.0 ng 。吡铂及其杂质的平均分离度大于2。结论:建立的方法特异性好,灵敏度高,重复性好,可为吡铂及其杂质的质量控制提供科学依据。