This paper presents a new approach that provides scaling the LCL-filter inductances based on the harmonic analysis of the filter output current. The approach considers the filter design together with the inverter control, both together, improving the system stability and the dynamic response. The model and general guidelines for selecting the filter parameters, taking into account the variation of the grid equivalent inductor and the use of non-linear inductances, are presented. The proposed control system makes use of feed-forward control in order to increase performances of the feedback control and eliminates the need of synchronization procedure. Simulation tests with a 15 kW three-phase VSI with a LCL filter have proved the effectiveness of the proposed approach.
机译:本文提出了一种基于滤波器输出电流的谐波分析来缩放LCL滤波器电感的新方法。该方法将滤波器设计与逆变器控制一起考虑,从而提高了系统稳定性和动态响应。提出了模型和选择滤波器参数的一般准则,其中考虑了电网等效电感的变化和非线性电感的使用。所提出的控制系统利用前馈控制以提高反馈控制的性能,并消除了同步过程的需要。使用带有LCL滤波器的15 kW三相VSI进行的仿真测试证明了该方法的有效性。