首页> 外文会议>2014 Electric Power Quality and Supply Reliability Conference >Assessment of transmission network voltage unbalance in connection of high-speed electrical railway connection
【24h】

Assessment of transmission network voltage unbalance in connection of high-speed electrical railway connection

机译:高速铁路连接中输电网络电压不平衡的评估

获取原文
获取原文并翻译 | 示例

摘要

High-speed electrical railway connections are known to cause additional voltage unbalance and other unwanted interactions in the transmission network. In order to assess the influence of different high-speed electrical railway connection options and their characteristics in case of possible Rail Baltic project a comprehensive study was made. This paper provides a discussion about the influence of different type of railway network connection transformers in connection of different load characteristics and contingencies in the railway system. Paper includes an assessment and analysis about possible technical solutions in order to minimize possible adverse interactions between the railway and transmission network. This information is essential for the utilities when planning possible high-speed railway connections and enables to determine possible railway influence and compose adequate connection requirements and specifications.
机译:众所周知,高速电气铁路连接会导致传输网络中额外的电压不平衡和其他不良相互作用。为了评估不同的高速电气铁路连接方案的影响及其在可能的波罗的海项目中的特征,进行了全面的研究。本文讨论了不同类型的铁路网连接变压器对铁路系统中不同负载特性和突发事件的影响。文件包括对可能的技术解决方案的评估和分析,以最大程度地减少铁路与输电网络之间可能产生的不利相互作用。在规划可能的高速铁路连接时,此信息对于公用事业至关重要,并且可以确定可能的铁路影响并制定适当的连接要求和规格。