首页> 外文会议>2012 International Conference on High Voltage Engineering and Application. >The measurement method research for leakage current based on LED optical fiber sensor
【24h】

The measurement method research for leakage current based on LED optical fiber sensor

机译:基于LED光纤传感器的漏电流测量方法研究

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

The leakage current is a main characteristic quantity of contamination level of transmission lines insulator surfaces, measuring insulator leakage current is currently the principal means to monitor the contamination level, but because the environment of transmission lines is very complex, electromagnetic interference will must produce much noise at the time of collecting and testing leakage current, sometime we also get the full wave or half cycle, that means some ways to realize selective measurements, to improve the current sensor's abilities of anti-jamming, selectivity and accuracy when the sensors measure insulator leakage current, an optical fiber sensor was employed to measure leakage current of the insulator strings, which used LED as the photoelectric conversion and light signal stability to detect the current. Some tests in lab were operated that results approved that the optical fiber sensor could achieve selective measurement of leakage current waves, the positive half cycle or negative half cycle, and of cause the full cycle current could be monitored after the differential circuit was improved. It had a great degree of linearity fitting, its sensitivity reached 40mV/mA, and their pertinence coefficients of linear fitting are all more than 99.94%. Its frequency response was 1Hz∼10 kHz, which can meet the basic requirements of the leakage current measurement.
机译:泄漏电流是传输线绝缘子表面污染程度的主要特征量,测量绝缘子泄漏电流是目前监测污染程度的主要手段,但是由于传输线环境非常复杂,电磁干扰必然会产生很大的噪声。在收集和测试泄漏电流时,有时我们还会得到全波或半周波,这意味着一些方法可以实现选择性测量,从而提高电流传感器在测量绝缘子泄漏时的抗干扰能力,选择性和准确性电流时,使用光纤传感器测量绝缘子串的泄漏电流,并以LED作为光电转换和光信号稳定性来检测电流。在实验室进行的一些测试表明,该光纤传感器可以实现泄漏电流波,正半周或负半周的选择性测量,并且在改善差分电路之后可以监测全周电流。它具有很高的线性拟合度,灵敏度达到40mV / mA,线性拟合的相关系数均大于99.94%。其频率响应为1Hz〜10 kHz,可以满足泄漏电流测量的基本要求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号