首页> 外文会议>14th International Conference on Nuclear Engineering 2006(ICONE14) vol.1 >ONE-LOOP OPERATION OF PRIMARY HEAT TRANSPORT SYSTEM IN MONJU DURING HEAT TRANSPORT SYSTEM MODIFICATIONS
【24h】

ONE-LOOP OPERATION OF PRIMARY HEAT TRANSPORT SYSTEM IN MONJU DURING HEAT TRANSPORT SYSTEM MODIFICATIONS

机译:传热系统修改期间,Monju中的主传热系统单循环运行

获取原文
获取原文并翻译 | 示例

摘要

MONJU is a prototype fast breeder reactor (FBR). Modification work commenced in March 2005. Since June 2004, MONJU has changed to one-loop operation of the primary heat transport system (PHTS) with all of the secondary heat transport systems (SHTS) drained of sodium. The purposes of this change are to shorten the modification period and to reduce the cost incurred for circuit trace heating electrical consumption. Before changing condition, the following issues were investigated to show that this mode of operation was possible. The heat loss from the reactor vessel and the single primary loop must exceed the decay heat by an acceptable margin but the capacity of preheaters to keep the sodium within the primary vessel at about 200℃ must be maintained. With regard to the heat loss and the decay heat, the estimated heat loss in the primary system was in the range of 90-170kW in one-loop operation, and the calculated decay heat was 21.2kW. Although the heat input of the primary pump was considered, it was clear that circuit heat loss greatly exceeded the decay heat. As for preheaters, effective capacity was less than the heat loss. Therefore, the temperature of the reactor vessel room was raised to reduce the heat loss. One-loop operation of the PHTS was able to be executed by means of these measures. The cost of electrical consumption in the power plant has been reduced by one-loop operation of the PHTS and the modification period was shortened.
机译:MONJU是原型快速增殖反应堆(FBR)。改造工作于2005年3月开始。自2004年6月起,MONJU已更改为一次热传输系统(PHTS)的单回路运行,所有二次热传输系统(SHTS)都排干了钠。进行此更改的目的是缩短修改周期并减少电路走线加热耗电量的成本。在更改条件之前,已对以下问题进行了调查,以表明这种操作模式是可行的。反应堆容器和单个主回路的热损失必须超过衰减热可接受的余量,但是必须保持预热器将钠保持在主容器中的温度约为200℃的能力。关于热损失和衰减热,在一次循环运行中,一次系统中估计的热损失在90-170kW范围内,计算的衰减热为21.2kW。尽管考虑了主泵的热量输入,但很明显,电路的热量损失大大超过了衰减热量。对于预热器,有效容量小于热量损失。因此,提高反应堆容器室的温度以减少热损失。通过这些措施,可以执行PHTS的单循环操作。通过PHTS的单回路运行,降低了电厂的用电成本,缩短了修改周期。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号