首页> 外文会议>11th International Conference on Electrical Machines and Systems(第11届国际电机与系统会议)论文集 >Three-Phase PWM Inverters with Three-Phase Output Transformer and Three-Phase Filter Inductor
【24h】

Three-Phase PWM Inverters with Three-Phase Output Transformer and Three-Phase Filter Inductor

机译:带有三相输出变压器和三相滤波电感的三相PWM逆变器

获取原文

摘要

In this paper, the different influences of three-limb and multi-limb transformer with Star-Star or Delta-Star connection, three-limb filter inductor, multi-limb filter inductor and position of the LC filter in a three-phase PWM inverter have been analyzed in detail in stationary dq0 frame. The analysis show that three-phase transformer with different limb numbers and connection types have different influences on the ability of suppressing unbalanced load and provide different strategies for output voltage control. Meanwhile, the position of a three-phase filter inductor and filter capacitor will impact the performance and control options of a three-phase inverter at unbalanced load differently. Tests on a 90-kVA 400Hz three-phase power supply with a three-phase five-limb transformer give good proof of the correctness and effectiveness of the theoretical analysis.
机译:本文研究了星形-星形或三角形-星形连接的三臂和多臂变压器,三臂滤波电感,多臂滤波电感以及三相PWM逆变器中LC滤波器位置的不同影响已在固定dq0帧中进行了详细分析。分析表明,不同肢数和连接类型的三相变压器对抑制不平衡负载的能力有不同的影响,并提供了不同的输出电压控制策略。同时,三相滤波电感和滤波电容的位置会在不平衡负载下对三相逆变器的性能和控制选项产生不同的影响。在具有三相五臂变压器的90kVA 400Hz三相电源上进行的测试很好地证明了理论分析的正确性和有效性。