Pengaruh Beban Pendinginan terhadap Temperatur Sistem Residential Air Conditioning Hibrida dengan Kondensor Dummy Tipe Multi Helical Coil Menggunakan Refrigeran Hidrokarbon

机译:制冷负荷对含碳氢制冷剂的多螺旋线圈虚拟冷凝器混合式住宅空调系统温度的影响

摘要

One way to save the energy is to improve the energy efficiency with combining two different equipmentsbecome one new double-function or hybrid equipment. Hybrid air conditioning can improve energy efficiency byremoving waste heat to the environment through condenser for heating water. The objective of this experimentalstudy is to investigate the effect of cooling load to system temperature of vapor-compression cycle hybrid airconditioning system with multi helical tipe of dummy condenser. The test was conducted with several coolingload variations (0, 1000, 2000 and 3000 Watt) as residential cooling load simulation. The result showed that therefrigerant temperature while using HCR-22 was obtained about 67.47 °C to 72.93 °C. The temperature ofrefrigerant was increased as well as the applied cooling load to be increased. The temperature of refrigeranthad more heat which to be absorbed and released into the environment so that the produced water temperaturewasalso increased. Hot water temperature of the ACWH system using HCR-22 refrigerant was obtained about41.01-44.96 ˚C.
机译:节约能源的一种方法是通过将两种不同的设备组合成为一种新的双功能或混合设备来提高能源效率。混合空调可通过冷凝器加热水将废热排到环境中,从而提高能源效率。本实验研究的目的是研究冷却负荷对虚拟冷凝器多螺旋尖端的蒸汽压缩循环混合空调系统系统温度的影响。作为住宅制冷负荷模拟,在几种制冷负荷变化(0、1000、2000和3000瓦)下进行了测试。结果表明,使用HCR-22时的制冷剂温度约为67.47°C至72.93°C。制冷剂的温度增加,而施加的冷却负荷增加。制冷剂的温度有更多的热量被吸收并释放到环境中,从而使采出水的温度也升高了。使用HCR-22制冷剂的ACWH系统的热水温度约为41.01-44.96°C。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号