U-value of glazed elements is often a critical issue because these components, due to theirudsmall thickness and to the poor resistance of the glass and frame materials, cause veryudrelevant heat fluxes. This paper presents an investigation on the thermal properties of audparticular glazed component: the glassblock. Generally standard glassblocks have high U-udvalues in comparison to the maximum values allowed by energy efficiency standards forudglazed surfaces. This paper reports a summary of possible solutions that could improve theudperformances of the glassblock. A set of new configurations of the glassblock has beenuddefined by schematic models and their overall thermal resistance has been assessed by theudmeans of Finite Element software. The resulting performances are presented in terms of theudglobal thermal transmittance of the modified glassblocks, also considering the effects ofudsealing and mortar. The paper also shows some significant potential improvements to addressudnew production lines.
机译:上釉元素的U值通常是一个关键问题,因为这些组件由于厚度过小以及玻璃和框架材料的电阻差而导致非常不相关的热通量。本文介绍了一种特殊的玻璃组件:玻璃块的热性能。通常,与能效标准所允许的釉面相比,标准的玻璃块具有较高的U / ud值。本文总结了可能改善玻璃砖性能的可能解决方案。原理图模型已定义了玻璃砖的一组新配置,其总热阻已通过有限元软件进行了评估。所得的性能以改性玻璃砖的整体导热率表示,同时考虑了封口和砂浆的影响。本文还显示了解决新生产线方面的一些重大潜在改进。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号