首页> 美国政府科技报告 >Performance Criteria Guideline for Three Explosion Protection Methods of Electrical Equipment Rated Up to 15,000 Volts AC
【24h】

Performance Criteria Guideline for Three Explosion Protection Methods of Electrical Equipment Rated Up to 15,000 Volts AC

机译:电气设备三种防爆方法的性能标准指南,额定电压高达15,000伏交流电

获取原文

摘要

The Bureau of Mines, U.S. Department of the Interior, is reviewing explosion protection methods for use in gassy coal mines. This performance criteria guideline is an evaluation of three explosion protection methods of machines electrically powered with voltages up to 15,000 volts ac. A sufficient amount of basic research has been accomplished to verify that the explosion-proof and pressurized enclosure methods can provide adequate explosion protection with the present state of the art up to 15,000 volts ac. The routine application of the potted enclosure as a stand-alone protection method requires further investigation or development in order to clarify performance criteria and verification-certification requirements. An extensive literature search, a series of high-voltage tests, and a design evaluation of the three explosion protection methods performed at the White Sands Test Facility indicate that the explosion-proof, pressurized, and potted enclosures can all be used to enclose up to 15,000 volts ac, if the performance criteria and verification-certification requirements recommended in this guideline are implemented.