The performance of the computer programs (Spectran F and Spectran-III) in resolving the exp 137 Cs-sup(110m)Ag double peak at 661.6-657.7 keV in the gamma-ray spectrum was investigated. In the experiments, the intensity ratios of both lines in the double peak were varied from 0.1 to 60. The results obtained show, that both programs have almost the same performance in resolving the double peak investigated, with slight superiority of Spectran-F. If accuracy better than 5% is desired, the peak intensity ratio in the dublet must be kept below 10. (ERA citation 08:002901)