首页> 美国政府科技报告 >Capillary Column Gas Chromatography, Resonance Enhanced Multiphoton Ionization, Time-of-Flight Mass Spectrometry Laser-Induced Fluorescence, Flame Ionization Detection System for the Determination of Polynuclear Aromatic Compounds
【24h】

Capillary Column Gas Chromatography, Resonance Enhanced Multiphoton Ionization, Time-of-Flight Mass Spectrometry Laser-Induced Fluorescence, Flame Ionization Detection System for the Determination of Polynuclear Aromatic Compounds

机译:毛细管柱气相色谱,共振增强多光子电离,飞行时间质谱激光诱导荧光,火焰离子化检测系统测定多核芳香族化合物

获取原文

摘要

Of the thousands of chemical compounds that have been deemed mutagenic or carcinogenic, it is generally agreed that the polynuclear aromatic hydrocarbons (PAC) are among the most potent. Because of the wide range of potency of PAC, even among geometric isomers and substitutional derivatives, it is important to fully characterize these samples. This task is a formidable one, usually requiring elaborate sample clean-up and fractionation prior to analysis. A multidimensional, laser-based analytical instrument has been developed that, when utilized to the full extent of its capabilities, could be the solution to this complex analytical problem. The overall technique is termed Capillary Column Gas Chromatography, Resonance Enhanced Multiphoton Ionization, Time-Of-Flight Mass Spectrometry, Laser-induced Fluorescence, with parallel Flame Ionization Detection (CC/GC-REMPI-TOF/MS-LIF-FID). This system combines the selectivity and sensitivity of two complementary laser-based methods, REMPI and LIF, with an extremely powerful and proven analytical tool, GC/MS. The GC effluent passes through the ion source of a TOF/MS, where it is interrogated by a tunable ultraviolet laser beam. All laser-analyte interaction products (cations, electrons, and photons) are simultaneously monitored utilizing the TOF/MS, a total electron current detector (TECD), and a LIF detector. The simultaneous availability of this information simplifies the characterization task. The present absolute detection limits for several PAC have been determined to be in the low picogram range. Also, a linear dynamic range of approximately four orders of magnitude has been established for the TECD, indicating that this technique is both sensitive and quantitative. Further, the use of deuterated analogs, of selected PAC, as internal reference standards greatly assists in quantitation. 219 refs., 37 figs., 13 tabs. (ERA citation 11:041188)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号