首页> 美国政府科技报告 >An Evaluation of Real and Programmed Defect Conditions in HIP Discs Using Holosonics' System 200 Scanned Acoustical Holography Imaging System.
【24h】

An Evaluation of Real and Programmed Defect Conditions in HIP Discs Using Holosonics' System 200 Scanned Acoustical Holography Imaging System.

机译:用Holosonics系统200扫描声全息成像系统评估HIp光盘中的实际和程序缺陷条件。

获取原文

摘要

This report documents the successful inspection of HIP discs using Holosonics' System 200 Scanned Acoustical Holography Inspection System. The System 200 provides hard copy photographic images of internal material structural conditions. These acoustical images photos depict plan view, section view, 3-D projected views and reconstructed acoustical holography images of both real and programmed anomalous conditions within the HIP discs provided for this study. A total of 13 test specimens containing both real and programmed defects were examined in order to provide a meaningful data presentation documenting the adaptability of the System 200 to production inspection of HIP discs. A recommedned system configuration is presented in the conclusion of this report. (Author)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号