A measurement campaign was undertaken in Ny-Alesund, Spitsbergen (78 deg 55'N, 11 deg 90'E) during April and May 2003. Four mercury depletion events (MDE) were observed during the study. Three research groups measured reactive gaseous mercury (RGM) at three different measurement spots. All groups observed increased concentrations of RGM as concentrations of GEM decreased. Recorded concentrations of RGM ranged from less than 7 to 450 pg/m~3. Differences between both measured parallels and the measurements sites were observed, even though no significant differences in the mean GEM concentrations were revealed between the measurement spots.
机译:在2003年4月至5月期间,在斯匹次卑尔根州Ny-Alesund进行了一次测量活动(北纬78度55',东经11度90°)。在研究过程中观察到了四次汞耗竭事件。三个研究小组在三个不同的测量点测量了反应性气态汞(RGM)。所有组均观察到随着GEM浓度的降低,RGM的浓度增加。记录的RGM浓度范围小于7到450 pg / m〜3。即使在测量点之间没有发现平均GEM浓度有显着差异,也观察到了两个平行测量点和两个测量点之间的差异。