首页> 外文期刊>Journal of Clinical Microbiology >Evaluation of automated BACTEC MGIT 960 system for testing susceptibility of Mycobacterium tuberculosis to four major antituberculous drugs: comparison with the radiometric BACTEC 460TB method and the agar plate method of proportion.
【24h】

Evaluation of automated BACTEC MGIT 960 system for testing susceptibility of Mycobacterium tuberculosis to four major antituberculous drugs: comparison with the radiometric BACTEC 460TB method and the agar plate method of proportion.

机译:用于测试结核分枝杆菌对四种主要抗结核药物敏感性的自动化 BACTEC MGIT 960 系统评估:与辐射 BACTEC 460TB 方法和琼脂平板比例法的比较。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

We evaluated the performance of BACTEC MGIT 960 for automated testing of the susceptibility of 133 strains of Mycobacterium tuberculosis to streptomycin, isoniazid, rifampin, and ethambutol. The BACTEC MGIT 960 results were compared with those obtained with the radiometric BACTEC 460TB system, and when there was disagreement, the method of proportion on agar plates was used as a reference method. Strains resistant to the critical concentration of streptomycin, isoniazid, or ethambutol were also tested with a second, higher concentration. The overall agreement between the two systems was 96.7, and the 18 discrepancies were resolved in favor of BACTEC 460TB in 11 cases and in favor of BACTEC MGIT 960 in 7, a difference which was not statistically significant. Apart from the assay's low specificity for ethambutol, which was low for the radiometric assay as well, good sensitivity and specificity values characterized BACTEC MGIT 960. The average time required for completion of the test was 2.5 days shorter with BACTEC 460TB. In conclusion, BACTEC MGIT 960 appears to be a suitable replacement for the radiometric method of antimicrobial susceptibility testing of M. tuberculosis. The problem of frequent contamination of BACTEC MGIT 960 tests needs to be quickly resolved; in fact, 14 strains had to be reprocessed because of contamination.
机译:我们评估了 BACTEC MGIT 960 自动检测 133 种结核分枝杆菌菌株对链霉素、异烟肼、利福平和乙胺丁醇的敏感性的性能。将BACTEC MGIT 960的结果与辐射BACTEC 460TB系统的结果进行比较,当存在分歧时,使用琼脂平板上的比例方法作为参考方法。对链霉素、异烟肼或乙胺丁醇临界浓度耐药的菌株也用第二种更高浓度的菌株进行了测试。两个系统之间的总体一致性为96.7%,18个差异在11个案例中支持BACTEC 460TB,在7个案例中支持BACTEC MGIT 960,差异无统计学意义。除了该测定对乙胺丁醇的低特异性(辐射测定也低)外,BACTEC MGIT 960 具有良好的灵敏度和特异性值。使用BACTEC 460TB时,完成测试所需的平均时间缩短了2.5天。总之,BACTEC MGIT 960 似乎是结核分枝杆菌抗菌药物敏感性测试辐射测量方法的合适替代品。BACTEC MGIT 960测试频繁污染的问题需要迅速解决;事实上,由于污染,有14种菌株必须进行再加工。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号