A satisfactory level of mechanical properties forhot rolled strip can only be reached by accurate control of therun-out table cooling. A model and a control system arepresented, which enable to adjust the cooling pattern to therequirements specific to the product being rolled. The model isauto-adaptative. Empirical tables are used to characterize heatexchange efficiency between the product and the cooling water.Thanks to this model, significant improvements have beenobtained for rolling performance and product quality.
展开▼
Laboratoire de Physico - & Toxico-Chimie (LPTC) des Systems Naturels UMR 5472 CNRS, Universite de Bordeaux I, 351, cours de la Liberation 33405 Talence Cededx, France.;