In addition to salt deposition methods prescribed in ISO 16539:2013, we have developed a simple salt deposition method for multiple specimens. This method also includes the possibility to suppress the variations of the amount of salt deposition. Not only the salt deposition characteristic, but also the influence on corrosion was examined experimentally. The newly developed method provided salt deposition that was approximately equivalent level of the quantity prescribed ISO 16539:2013. The results of corrosion test with this new salt deposition method showed good agreement with those of other salt deposition methods prescribed in ISO.
机译:除了 ISO 16539:2013 中规定的盐沉积方法外,我们还开发了一种适用于多个样品的简单盐沉积方法。该方法还包括抑制盐沉积量变化的可能性。不仅通过实验研究了盐沉积特性,还研究了其对腐蚀的影响。新开发的方法提供的盐沉积水平与ISO 16539:2013规定的量大致相当。这种新的盐沉积方法的腐蚀试验结果与ISO规定的其他盐沉积方法的结果非常吻合。