首页> 外文期刊>journal of applied polymer science >Gas permeation of polymer blends. III. Poly(vinyl chloride) (PVC)/chlorinated polyethylene (CPE)
【24h】

Gas permeation of polymer blends. III. Poly(vinyl chloride) (PVC)/chlorinated polyethylene (CPE)

机译:Gas permeation of polymer blends. III. Poly(vinyl chloride) (PVC)/chlorinated polyethylene (CPE)

获取原文
           

摘要

AbstractThe permeabilityP, diffusivityD, and activation energy for diffusion,ED, of He, O2, N2, and CO2were determined for blends of PVC/chlorinated polyethylene (CPE), where the chlorine content of the CPE components varied: 36 wt‐ for CPE‐1, 42 wt‐ for CPE‐2, and 48 wt‐ for CPE‐3. The difference in thermal expansion coefficients Δα above and below the glass transition temperatureTgof the polymers and the fractional free volumeVgof the polymers at theirTgwere determined. Density and crystallinity measurements for the blends were also carried out as in the earlier work (Shur and Rånby,J. Appl. Polym. Sci.,19, 1337 (1975)). Dynamic mechanical measurements of the blends were made using a torsion pendulum at about 1 Hz.PandDdecreased, butEDincreased with increasing CI content of CPE in the blends.PandDfor the blends showed no additivity. The permeability indicated phase inversion for blend compositions at about 10 of CPE‐1 and CPD‐2 by weight. The experimental and the calculated densities were largely the same for PVC/CPE‐1 blends; but for PVC/CPE‐2 and PVC/CPE‐3 blends, the experimental values were higher than the calculated ones. The Δα andVgvalues for PVC and the three CPE samples decreased with increasing CI content in the polymers. Dynamic mechanical measurements indicate that PVC/CPE‐1 and PVC/CPE‐2 blends form largely incompatible blends, while PVC/CPE‐3 blends are compatible to some extent. There is some weak interaction between PVC and CPE‐3 giving a low level of compatibility. The solubility of gases obtained from time‐lag measurements of diffusion for 50/50 blends decreased for He, O2, and N2, but increased for CO2with increasing Cl content in CPE. The solubility of He, O2and N2shows a positive correlation with the Lennard‐Jones force constant ϵ/k. However, a deviation from the linear relation between ϵ/kand InSwas observed for CO2and the deviation became larger with increasing Cl content in CPE. The abnormally high solubility of CO2is probably due to the high polarizability of this gas. The heat of solution ΔHsindicates that for He the sorption process may be a molecular slip process (endothermic), but for other gases the sorption may proceed by a dissolution process (exothermic). There is a large difference between the calculated solubility for the blends assuming incompatibility and the experimental values from time‐lag measurements. This may partly be due to the uncertainty of sorption values obtained from the time‐lag method and/or partly to changes of sorption modes by interaction between PVC and CPE in the blends. The resulting transport behavior of the blends is discussed on the basis of the free volume concept

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号