首页> 外文期刊>review of scientific instruments >Measurement of the wall radiation in soft xhyphen;ray region in PDX
【24h】

Measurement of the wall radiation in soft xhyphen;ray region in PDX

机译:Measurement of the wall radiation in soft xhyphen;ray region in PDX

获取原文
           

摘要

A detector setup with three LNhyphen;cooled Si(Li) diodes is used to measure soft xhyphen;ray spectra (0.8ndash;20 keV) emitted from the inside walls of the PDX vessel during the plasma discharge. The setup is part of a pulsehyphen;heighthyphen;analysis system, which is used to measure the plasma and wall radiation simultaneously at five different radial positions. The wall and the plasma radiation are measured under different plasma conditions (e.g., OH and neutral beam heating). The wall radiation is very much increased during the neutral beam heating, with an enhancement factor of at least 10 over the OH wall radiation. Since we measure the plasma and the wall radiation at the same time, the measurements allow the conclusion that the wall radiation can be attributed essentially to fluorescence (line radiation, e.g.,Tihyphen;Kagr;) and scattering (continuum part of the wall radiation spectrum). The fluorescence and the scattering are both caused by soft xhyphen;ray radiation flux coming from the plasma. There seems to be no need to invoke other, more exotic causes for the wall radiation, for example, charge particle bombardment of the wall.