A new tympanic thermometer is analyzed and tested experimentally. An electrically calibrated pyroelectric detector of special configuration is employed to determine a person's body temperature. An energy-storage, power-supply-isolated capacitor is used as the electrical heating reference. The new thermometer design has an accuracy within +/-0.1 degrees C with a 90% confidence and is immune to ambient temperature, detector aging, and parameter variations. An equivalent-circuit model is established in the analysis to account for the heat exchanges among the tympanum, the surroundings, and the detector as well as for the electrothermal behavior of the detector. The model provides effective simulation of the thermometer with PSPICE. Critical parameters governing the accuracy and the Limitation of the tympanic thermometer are also pointed out by the simulation. (C) 1998 Optical Society of America. [References: 22]
机译:新型鼓膜温度计经过分析和测试。采用特殊配置的电校准热释电探测器来确定人的体温。储能,电源隔离的电容器用作电加热参考。新的温度计设计具有+/- 0.1摄氏度以内的准确度,置信度为90%,并且不受环境温度,检测器老化和参数变化的影响。在分析中建立了等效电路模型,以考虑到鼓膜,周围环境和检测器之间的热交换以及检测器的电热行为。该模型可使用PSPICE对温度计进行有效的仿真。仿真还指出了控制鼓膜温度计的准确性和局限性的关键参数。 (C)1998年美国眼镜学会。 [参考:22]