Accurate snowfall measurement is challenging because it depends on the precipitation gauge used, meteorological conditions, and the precipitation microphysics. Upstream of weighing gauges, the flow field is disturbed by the gauge and any shielding used usually creates an updraft, which deflects solid precipitation from falling in the gauge, resulting in significant undercatch. Wind shields are often used with weighing gauges to reduce this updraft, and transfer functions are required to adjust the snowfall measurements to consider gauge undercatch. Using these functions reduces the bias in precipitation measurement but not the root-mean-square error (RMSE). In this study, the accuracy of the Hotplate precipitation gauge was compared to standard unshielded and shielded weighing gauges collected during the WMO Solid Precipitation Intercomparison Experiment program. The analysis performed in this study shows that the Hotplate precipitation gauge bias after wind correction is near zero and similar to wind corrected weighing gauges. The RMSE of the Hotplate precipitation gauge measurements is lower than weighing gauges (with or without an Alter shield) for wind speeds up to 5 m s(-1), the wind speed limit at which sufficient data were available. This study shows that the Hotplate precipitation gauge measurement has a low bias and RMSE due to its aerodynamic shape, making its performance mostly independent of the type of solid precipitation.
机译:准确的降雪量测量具有挑战性,因为它取决于使用的降水量计、气象条件和降水微物理。称重仪表上游的流场受到仪表的干扰,使用的任何屏蔽通常会产生上升气流,从而使固体降水偏离仪表内的下落,导致严重的捕捉不足。经常使用挡风罩与称重仪表来减少这种上升气流,并且需要传递函数来调节降雪量测量,以考虑量规不足。使用这些函数可以减少降水测量中的偏差,但不能减少均方根误差(RMSE)。在这项研究中,将热板式雨量计的精度与WMO固体降水相互比较实验项目期间收集的标准无屏蔽和屏蔽称重计进行了比较。本研究中进行的分析表明,风修正后的热板雨量计偏差接近于零,与风修正称重计类似。对于风速高达5 m s(-1)的情况,热板雨量计测量的RMSE低于称重计(带或不带Alter护罩),风速限制是有足够数据可用的。这项研究表明,由于其空气动力学形状,热板雨量计测量具有较低的偏差和RMSE,使其性能基本上独立于固体降水的类型。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号