首页> 外文期刊>Applied optics >In situ and on-line monitoring of CO in an industrial glass furnace by mid-infrared difference-frequency generation laser spectroscopy
【24h】

In situ and on-line monitoring of CO in an industrial glass furnace by mid-infrared difference-frequency generation laser spectroscopy

机译:中红外差频发生激光光谱技术在工业玻璃炉中原位和在线监测CO

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A compact mid-infrared (MIR) laser spectrometer based on difference-frequency generation (DFG) is applied as a portable and sensitive gas sensor for industrial process control and pollutant monitoring. We demonstrate the performance of such a MIR DFG gas sensor by recording the absorption spectra of the carbon monoxide (CO) P(28) absorption line in the atmosphere of a gas-fired glass melting furnace. For a gas temperature of approximately 1100℃, the CO concentration in the recuperator channel is measured to be 400 parts per million.
机译:基于差频发生(DFG)的紧凑型中红外(MIR)激光光谱仪被用作便携式,灵敏的气体传感器,用于工业过程控制和污染物监测。我们通过记录在燃气玻璃熔炉气氛中一氧化碳(CO)P(28)吸收线的吸收光谱来证明这种MIR DFG气体传感器的性能。对于大约1100℃的气体温度,测得的换热器通道中的CO浓度为百万分之400。