Abstract: Evaluation of Validity of the Urine Dipstick Test for Identification of Reduced Glomerular Filtration Rate in Japanese Male Workers Aged 40 Years and Over: Masatoshi Kawashima, et al. Department of Occupational Health, Graduate School of Medical Sciences, Kitasato University-Objectives: We evaluated the validity of the urine dipstick test for identifying reduced glomerular filtration rate (GFR) in male workers. Methods: This study was conducted in male workers aged > 40 yr. Reduced GFR was categorized as either estimated GFR (eGFR) < 60 m//min/1.73 m2 (eGFR < 60) or eGFR < 50 m//min/1.73 m2 (eGFR < 50). Four sets of criteria were used to evaluate the GFR on the basis of proteinuria excretion, as measured using the urine dipstick test. Receiver operating characteristic curves were created based on the sensitivity and specificity and used to calculate the area under the curve (AUC) and the 95% confidence intervals (Cl). Results: A total of 5,799 workers were included in this study. Use of an abnormal proteinuria criterion of 1+-3+ and a reduced GFR criterion of eGFR < 60 resulted in a sensitivity and specificity of 7.8% and 97.4%, respectively, while a reduced GFR criterion of eGFR < 50 resulted in a sensitivity and specificity of 37.8% and 97.4%, respectively. The AUC was 0.52 (95% Cl, 0.48-0.55) for eGFR < 60 and 0.70 (95% Cl, 0.59-0.80) for eGFR <50. Conclusions: In this study, 92.2% of participants with an eGFR < 60 and 62.2% of participants with an eGFR < 50 were overlooked in the urine dipstick test. These results suggest that the urine dipstick test only is not sufficient enough to identify reduced GFR and that both a urine dipstick test and other measures of GFR are required to reliably identify reduced GFR.
机译:摘要:40岁及以上的日本男性工人的尿液试纸法可用于确定肾小球滤过率降低的有效性评估:川岛正敏等。北里大学医学研究生院职业卫生学系-目的:我们评估了尿液试纸测试对男性工人肾小球滤过率降低(GFR)识别的有效性。方法:本研究在年龄大于40岁的男性工人中进行。降低的GFR分为估计GFR(eGFR)<60 m // min / 1.73 m2(eGFR <60)或eGFR <50 m // min / 1.73 m2(eGFR <50)。使用蛋白尿排泄,使用尿液试纸法测量了四组标准来评估GFR。基于灵敏度和特异性创建接收器工作特征曲线,并用于计算曲线下面积(AUC)和95%置信区间(Cl)。结果:本研究共纳入5799名工人。使用1 + -3 +的异常蛋白尿标准和降低的eGFR <60的GFR准则分别导致7.8%和97.4%的敏感性和特异性,而降低的eGFR <50的GFR准则导致敏感性和特异性。特异性分别为37.8%和97.4%。对于eGFR <60,AUC为0.52(95%Cl,0.48-0.55),对于eGFR <50为0.70(95%Cl,0.59-0.80)。结论:在这项研究中,尿液试纸法忽略了92.2%的eGFR <60的参与者和62.2%的eGFR <50的参与者。这些结果表明,尿量油尺测试仅不足以识别降低的GFR,并且需要尿液量尺测试和其他GFR测量值才能可靠地识别GFR降低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号