首页> 外文期刊>Journal of biomedical materials research. Part B, Applied biomaterials. >In vivo mechanical and histological characteristics of HA-coated implants vary with coating vendor.
【24h】

In vivo mechanical and histological characteristics of HA-coated implants vary with coating vendor.

机译:HA涂层植入物的体内力学和组织学特征随涂层供应商的不同而不同。

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this study was to evaluate the interface attachment strength and histology of hydroxylapatite (HA) coated and uncoated titanium and cobalt-chromium alloy implants. The canine transcortical plug model was utilized. Four different hydroxylapatite coatings were evaluated. In vitro analysis confirmed that all coatings met FDA guidelines for HA coatings. An unspecified FDA parameter, porosity was found to range from 5-15%. Mechanical testing of the bone-implant interface demonstrated large variation in the performance of the coatings. However, further evaluation of two of the coatings did not demonstrate variations in mechanical characteristics. The histologic findings confirmed the mechanical testing results. The coatings which demonstrated the best mechanical characteristics had excellent bone apposition and uniformity and maintenance of the HA coating at all time periods upon histologic evaluation. Conversely, the coatings which demonstrated inferior mechanical characteristics demonstratedvariable amounts of bone apposition and moderate to severe coating degradation and breakup. Cell-mediated osteolysis was observed in regions of severe coating degradation, and particle migration was noted in regions far from the interface. It was hoped that the four coatings would behave similarly as they all met current FDA guidelines. The only parameter which differed significantly among the coatings was coating porosity. Our results indicate that coatings with large porosities were associated with increased coating degradation and poor mechanical performance and osteolysis at the bone-coating interface.
机译:这项研究的目的是评估羟基磷灰石(HA)涂覆和未涂覆的钛和钴铬合金植入物的界面附着强度和组织学。使用犬的经皮质塞模型。评价了四种不同的羟基磷灰石涂层。体外分析证实,所有涂料均符合FDA的HA涂料指南。 FDA未指定参数孔隙率范围为5-15%。骨-植入物界面的机械测试表明涂层的性能差异很大。然而,对两种涂层的进一步评估并未显示出机械特性的变化。组织学结果证实了机械测试结果。表现出最佳机械性能的涂层在组织学评估后的所有时间段均具有出色的骨附着性,均匀性和HA涂层的维持性。相反,表现出较差的机械特性的涂层表现出可变的骨附着量,并且具有中等至严重的涂层降解和破裂。在严重的涂层降解区域观察到细胞介导的骨溶解,并且在远离界面的区域观察到颗粒迁移。希望这四种涂层的性能类似,因为它们都符合当前的FDA指南。涂层之间唯一显着不同的参数是涂层孔隙率。我们的结果表明,孔隙率大的涂层与涂层降解增加,机械性能差和骨涂层界面处的骨溶解有关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号