Scale modeling experiments were conducted in a 1/12th scale model of the underground transport passage of the main transformer of a hydropower station model. The influence of heat release rate and smoke exhaust rate on the smoke exhaust efficiency was investigated. Results showed that the smoke exhaust process was less efficient when the heat release rate was larger, and that better smoke control may be obtained with larger smoke exhaust rates. The results of the scale modeling experiments have been compared with full-scale experimental results in other studies. Through comparison, it can be concluded that the results of the scale modeling experiments may be extrapolated to full scale, and the spill plume has similar characteristics to the smoke generated directly from fires that had spread along the passage.
机译:在水电站模型主变压器的地下运输通道的1/12比例模型中进行了比例模型实验。研究了放热率和排烟率对排烟效率的影响。结果表明,当放热率较大时,排烟过程效率较低;排烟率较大时,可以更好地控制烟雾。规模建模实验的结果已与其他研究中的全面规模实验结果进行了比较。通过比较,可以得出结论,可以将比例建模实验的结果外推到完整比例,并且溢出羽流具有与直接沿通道蔓延的火灾直接产生的烟雾相似的特性。

著录项

  • 来源
    《Tunnelling and underground space technology》 |2013年第1期|111-118|共8页
  • 作者单位

    School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, PR China;

    School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, PR China;

    School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, PR China;

    School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, PR China;

    School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, PR China;

    Northwest Hydro Consulting Engineers, China Hydropower Engineering Consulting Croup Co., Xi'an 710065, PR China;

    Northwest Hydro Consulting Engineers, China Hydropower Engineering Consulting Croup Co., Xi'an 710065, PR China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    smoke exhaust efficiency; underground transformer passage; scale model; spill plume;

    机译:排烟效率;地下变压器通道;比例模型;溢羽;