A natural ventilation scheme was proposed for large underground spaces based on the top cover design. This is regarded as a design towards 'green' or 'sustainable' building. The main factors influencing the natural smoke extraction efficiency were studied by using orthogonal design method and CFD technique. A new model was built to estimate the feasibility of the natural ventilation scheme in case of fire accidents. Results show that when fire occurs in underground part of the building, smoke can be exhausted to the interlayer, which is added between the underground part and its top cover, and then the smoke spread along the ceiling of the interlayer to its open boundaries. When working together with smoke shafts, smoke screens can limit the spread of smoke and improve the smoke exhausting efficiency of shafts. In addition, whether the smoke can be vented above specified safety height both in underground part and in the interlayer can be theoretically estimated by the judging model constructed. In order to ensure safety smoke layer height, the size of the underground part is limited when the fire power is determinate. And it showed linear relationship between critical underground part size and critical fire power. The slop of the line decreases when smoke screens are added.
机译:根据顶盖设计,提出了针对大型地下空间的自然通风方案。这被认为是针对“绿色”或“可持续”建筑的设计。采用正交设计法和CFD技术研究了影响自然烟气抽排效率的主要因素。建立了一个新模型来估计发生火灾时自然通风方案的可行性。结果表明,当建筑物的地下部分发生火灾时,烟雾可以排到中间层,然后将其添加到地下部分及其顶盖之间,然后烟雾沿着中间层的天花板扩散到其开放边界。与烟井一起使用时,烟屏可以限制烟气扩散,并提高烟井的排烟效率。此外,通过构造的判断模型,可以从理论上估算出地下部分和中间层是否可以将烟雾排放到规定的安全高度以上。为了确保安全烟层的高度,在确定火力时要限制地下部分的大小。它显示了关键地下部分尺寸和关键火力之间的线性关系。添加烟幕时,线的斜率减小。

著录项

  • 来源
    《Tunnelling and underground space technology》 |2014年第9期|23-32|共10页
  • 作者单位

    Institute of Fire Science and Technology, Nanjing Tech University, Nanjing 210009, China Jiangsu Key Laboratory of Urban and Industrial Safety, Nanjing 210009, China;

    Institute of Fire Science and Technology, Nanjing Tech University, Nanjing 210009, China Jiangsu Key Laboratory of Urban and Industrial Safety, Nanjing 210009, China;

    Institute of Fire Science and Technology, Nanjing Tech University, Nanjing 210009, China Jiangsu Key Laboratory of Urban and Industrial Safety, Nanjing 210009, China;

    Institute of Fire Science and Technology, Nanjing Tech University, Nanjing 210009, China Jiangsu Key Laboratory of Urban and Industrial Safety, Nanjing 210009, China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Large underground spaces; Natural ventilation; Smoke screen; Critical size; Critical fire power;