Effects of ambient pressure on smoke back-layering in subway tunnel fires

机译:环境压力对地铁隧道火灾烟气背层的影响

获取原文
获取原文并翻译 | 示例
           

摘要

This paper investigates the effects of ambient pressure on smoke back-layering in subway tunnel fires with and without train blockage. A series of numerical simulations were conducted in a 1/4 small-scale tunnel with different heat release rates (40-160 kW), longitudinal ventilation velocities (0.2-0.8 m/s) and ambient pressures (60-100 kPa). The smoke back-layering lengths under different conditions are analyzed, and the results show that under the same heat release rate and ventilation velocity, the back-layering length increases with decreasing ambient pressure due to the weak inertial force of longitudinal airflow led by the low air density. The Li's and Zhang's models, which can well predict the smoke back-layering length under regular pressure, are modified for the reduced pressure. The constant increment of back-layering length between adjacent ambient pressures, which mainly depends on the heat release rate, is used to correct Li's model. The smoke back-layering length under the low ambient pressure can be predicted by this modified model without train blockage. With train blockage considered, new models are developed by introducing both equivalent and virtual fire sources for predicting the smoke back-layering length under the low ambient pressure, which is shown to well reproduce the simulation results.
机译:本文研究了在有和没有火车堵塞的情况下,环境压力对地铁隧道火灾烟气反层的影响。在1/4小型隧道中进行了一系列数值模拟,这些隧道具有不同的放热率(40-160 kW),纵向通风速度(0.2-0.8 m / s)和环境压力(60-100 kPa)。分析了不同条件下的烟气背层长度,结果表明,在相同的放热率和通风速度下,由于低气流导致的纵向气流的惯性力弱,烟气的背层长度随着环境压力的降低而增加。空气密度。可以很好地预测常压下的烟气背层长度的李氏和张氏模型已针对减压进行了修改。相邻环境压力之间的后层长度的恒定增量(主要取决于放热速率)用于校正李氏模型。通过这种改进的模型可以预测在低环境压力下的烟气背层长度,而不会造成火车阻塞。考虑到火车阻塞,通过引入等效和虚拟火源来开发新模型,以预测在低环境压力下的烟气背层长度,这可以很好地再现模拟结果。

著录项

  • 来源
    《Tunnelling and underground space technology》 |2018年第9期|134-142|共9页
  • 作者单位

    Nanjing Tech Univ, Coll Safety Sci & Engn, Jiangsu Key Lab Urban & Ind Safety, Nanjing 211800, Jiangsu, Peoples R China;

    Nanjing Tech Univ, Coll Safety Sci & Engn, Jiangsu Key Lab Urban & Ind Safety, Nanjing 211800, Jiangsu, Peoples R China;

    Nanjing Tech Univ, Coll Safety Sci & Engn, Jiangsu Key Lab Urban & Ind Safety, Nanjing 211800, Jiangsu, Peoples R China;

    Nanjing Tech Univ, Coll Safety Sci & Engn, Jiangsu Key Lab Urban & Ind Safety, Nanjing 211800, Jiangsu, Peoples R China;

    Univ Lille Nord France, ENSCL, UMET ISP R2Fire, Cite Sci Bat C7-CS 90108, F-59652 Villeneuve Dascq, France;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Ambient pressure; Back-layering length; Subway tunnel fire;