The concrete-filled steel tubular (CFST) arch is an effective new support form for mine/traffic tunnels in complex conditions, and the casing joints on the arch determine its global bearing capacity. Eighteen tests, including axial compression, eccentric-compression with different eccentricities, and pure bending tests, were carried out. The bearing behavior, failure mode and failure mechanism of the specimens with casing tubes were analyzed and compared with specimens without a casing tube. Failures are mainly caused by the local stress concentration on the CFST components or the casing tube at the contact positions. The compression-bending bearing capacities of the CFST casing joints were analyzed with the help of the M-u-N-u coordinate system. Each M-u-N-u relation is described by a straight line combined with a lateral parabola, and the M-u-N-u formulas were fitted. The bearing ability of a CFST casing joint is lower than that of a conventional CFST section, and the reduction rate of the square cross section is more obvious. The effects of the concrete grade, casing tube length, casing tube thickness and gap width on the compression-bending capacity were obtained through numerical simulation tests. The concrete strength is the main factor influencing the axial compression bearing capacity, while it is the casing tube length that mainly influences the bending bearing capacity. Suggestions for use in practice are finally proposed based on the above results.
机译:钢管混凝土(CFST)拱是复杂条件下矿山/交通隧道的一种有效的新支撑形式,拱上的套管接头决定了其整体承载力。进行了18个测试,包括轴向压缩,具有不同偏心率的偏心压缩和纯弯曲测试。分析了带套管试件的承载行为,破坏方式和破坏机理,并与无套管试件进行了比较。失效主要是由于CFST组件或套管在接触位置处的局部应力集中引起的。借助M-u-N-u坐标系分析了CFST套管接头的压缩弯曲承载力。每个M-u-N-u关系由一条直线和一个侧向抛物线描述,并且拟合了M-u-N-u公式。 CFST套管接头的承载能力低于常规CFST截面,方形截面的减小率更加明显。通过数值模拟试验,得出了混凝土等级,套管长度,套管厚度和间隙宽度对抗弯承载能力的影响。混凝土强度是影响轴向压缩承载力的主要因素,而套管长度则主要影响弯曲承载力。最后根据上述结果提出了实际使用的建议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号