In this paper, an integrated combined system of a photovoltaic (glass-glass) thermal (PV/T) solar water heater of capacity 2001 has been designed and tested in outdoor condition for composite climate of New Delhi. An analytical expression for characteristic equation for photovoltaic thermal (PV/T) flat plate collector has been derived for different condition as a function of design and climatic parameters. The testing of collector and system were carried out during February-April, 2007. It is observed that the photovoltaic thermal (PV/T) flat plate collector partially covered with PV module gives better thermal and average cell efficiency which is in accordance with the results reported by earlier researchers.
机译:本文设计了一个容量为2001的光伏(玻璃-玻璃)热(PV / T)太阳能热水器集成组合系统,并在室外条件下对新德里的复合气候进行了测试。根据设计和气候参数,针对不同条件推导了光伏热(PV / T)平板集热器特征方程的解析表达式。集热器和系统的测试是在2007年2月至4月进行的。观察到,部分覆盖有PV模块的光伏热(PV / T)平板集热器具有更好的热效率和平均电池效率,这与结果一致由早期研究人员报道。