首页> 外文期刊>Solar Energy >Statistical fault detection in photovoltaic systems
【24h】

Statistical fault detection in photovoltaic systems

机译:光伏系统中的统计故障检测

获取原文
获取原文并翻译 | 示例
           

摘要

Faults in photovoltaic (PV) systems, which can result in energy loss, system shutdown or even serious safety breaches, are often difficult to avoid. Fault detection in such systems is imperative to improve their reliability, productivity, safety and efficiency. Here, an innovative model-based fault-detection approach for early detection of shading of PV modules and faults on the direct current (DC) side of PV systems is proposed. This approach combines the flexibility, and simplicity of a one-diode model with the extended capacity of an exponentially weighted moving average (EWMA) control chart to detect incipient changes in a PV system. The one-diode model, which is easily calibrated due to its limited calibration parameters, is used to predict the healthy PV array's maximum power coordinates of current, voltage and power using measured temperatures and irradiances. Residuals, which capture the difference between the measurements and the predictions of the one-diode model, are generated and used as fault indicators. Then, the EWMA monitoring chart is applied on the uncorrelated residuals obtained from the one-diode model to detect and identify the type of fault. Actual data from the grid-connected PV system installed at the Renewable Energy Development Center, Algeria, are used to assess the performance of the proposed approach. Results show that the proposed approach successfully monitors the DC side of PV systems and detects temporary shading. (C) 2017 Elsevier Ltd. All rights reserved.
机译:光伏(PV)系统中的故障通常会难以避免,这些故障可能导致能量损失,系统关闭甚至严重的安全漏洞。必须在此类系统中进行故障检测以提高其可靠性,生产率,安全性和效率。在此,提出了一种基于模型的创新故障检测方法,用于及早检测PV模块的阴影和PV系统直流(DC)侧的故障。这种方法将一二极管模型的灵活性和简单性与指数加权移动平均值(EWMA)控制图的扩展功能相结合,可检测PV系统中的初始变化。由于其有限的校准参数,易于校准的一二极管模型可用于使用测得的温度和辐照度预测健康PV阵列的电流,电压和功率的最大功率坐标。捕获一二极管模型的测量值和预测值之间的差异的残差将被生成并用作故障指示器。然后,将EWMA监视图应用于从一二极管模型获得的不相关残差,以检测和识别故障类型。安装在阿尔及利亚可再生能源开发中心的并网光伏系统的实际数据用于评估所建议方法的性能。结果表明,所提出的方法成功地监控了光伏系统的直流侧并检测到了暂时的阴影。 (C)2017 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号