In Egypt and the Middle East, there is an obvious tendency of establishing new shopping malls and indoor commercial centers that provide collective facilities. However, they are accompanied by multiple design challenges including the provision of natural lighting for the interior spaces, which requires a careful consideration for the environmental design aspects. This research aims to provide a methodology to assess and optimize skylight designs to achieve better daylighting performance. A case study for a shopping mall in Cairo is selected where different skylight design configurations are examined. Skylight parametric variations include different opening ratios and visual transmittance values. Daylighting performance is tested in regards with daylit area coverage, potential for glare and accompanied energy consumption used for artificial lighting. A parametric simulation for 50 different cases are conducted and a multiple-criteria optimization is carried out to optimize material and ratio of size. Other parameters could be investigated in further researches. The optimum solution is further extracted and compared to the current base case. These results shows that early considerations in skylight and interior design could achieve more than 50% reduction in the overlit area, while achieving minor improvements in the daylit area. Yet, retrofitting measures are applicable for post construction and occupation periods.
机译:在埃及和中东,有一种明显的趋势是建立新的大型购物中心和提供集体设施的室内商业中心。然而,它们伴随着多种设计挑战,包括为室内空间提供自然采光,这需要对环境设计方面进行仔细考虑。这项研究旨在提供一种评估和优化天窗设计以实现更好的采光性能的方法。选择了开罗一家购物中心的案例研究,其中研究了不同的天窗设计配置。天窗参数变化包括不同的开口率和视觉透射率值。对日光性能进行了测试,涉及日光区域的覆盖范围,眩光的可能性以及用于人造照明的能耗。进行了50种不同情况的参数模拟,并进行了多标准优化以优化材料和尺寸比。其他参数有待进一步研究。进一步提取最优解,并将其与当前基本情况进行比较。这些结果表明,对天窗和室内设计的早期考虑可以使过光区域减少50%以上,而对日光区域进行较小的改进。但是,改造措施适用于后期施工和占用期间。

著录项

  • 来源
    《Solar Energy》 |2018年第8期|358-368|共11页
  • 作者单位

    Architectural Department, Faculty of Engineering, Cairo University;

    Architectural Department, American University in Cairo (AUC);

    Architectural Department, Faculty of Engineering, Cairo University;

    Architectural Department, Faculty of Engineering, Cairo University;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Parametric analysis; Commercial buildings; SRR; Hot climate;

    机译:参数分析;商业建筑;SRR;高温气候;