首页> 外文期刊>Solar Energy >Comparison of three models to estimate the slant path atmospheric attenuation in central receiver solar thermal plants under Indian climatic conditions
【24h】

Comparison of three models to estimate the slant path atmospheric attenuation in central receiver solar thermal plants under Indian climatic conditions

机译:三种模型估算中央接收机太阳能热电厂倾斜路径大气衰减的比较

获取原文
获取原文并翻译 | 示例
           

摘要

This paper compares three attenuation models for the distinct meteorological conditions of India and assesses the feasibility of using the satellite data to calculate the slant path extinction coefficient and the slant path transmissivity of the lower atmosphere. The attenuation models are compared for the sites of Pune, Kanpur, and Jaipur. The AERONET data is used with REST2 to model the direct normal irradiance and the total optical depth. The results indicate that the three models give similar transmissivity values for low aerosol concentrations. As the aerosol concentrations increase, the difference in the slant path transmissivity as calculated by two of the models increases with respect to the third reference model.The slant path transmissivity comparison shows that for AERONET AOD at 550 nm (AOD550) less than 0.3, the relative error in the transmissivity values estimated by two of the compared models with respect to the third model is not higher than 10 % for Pune, 18 % for Kanpur, and 12 % for Jaipur. The mean relative error in the slant path transmissivity values obtained from the reference model using MODIS data with respect to the values obtained using AERONET data is 4.8 %, 10.2 %, and 9.2 % for Pune, Kanpur, and Jaipur, respectively. A difference of 0.2 between AERONET AOD550 and MODIS AOD550 values resulted in a difference of 0.05-0.08 between the transmissivity values calculated by the reference model using AERONET AOD550 and using MODIS AOD550 for the three sites.
机译:本文比较了印度不同气象条件的三种衰减模型,并评估了使用卫星数据的可行性来计算倾斜路径消光系数和较低气氛的倾斜路径透射率。将衰减模型与浦那,坎普尔和斋浦尔的网站进行比较。 AERONET数据与REST2一起使用,以模拟直接正常辐照度和总光学深度。结果表明,这三种模型给出了低气溶胶浓度的透射率值。随着气溶胶浓度的增加,由两个模型计算的倾斜路径透射率的差异相对于第三参考模型增加。倾斜路径透射率比较表明,对于550nm(AOD550)的AeroNet AOD小于0.3,对于第三种模型的两个比较模型估计的透射率值中的相对误差不高于浦那的10%,kanpur的18%,斋浦尔的12%。从参考模型获得的斜路路径透射率的平均相对误差分别使用MODIS数据获得的关于使用AERONET数据获得的值为4.8%,10.2%和9.2%,分别用于浦那,坎普尔和斋浦尔。 AeroNet AOD550和MODIS AOD550值之间的0.2的差异导致由使用AeroNet AOD550计算的参考模型计算的透射率值与三个站点的Modis AOD550计算的透射率值之间的差异为0.05-0.08。

著录项

  • 来源
    《Solar Energy》 |2020年第2期|1042-1052|共11页
  • 作者单位

    Indian Inst Technol Dept Energy Sci & Engn Mumbai 400076 Maharashtra India;

    German Aerosp Ctr DLR Inst Solar Res Plataforma Solar Almeria PSA Ctra Senes S-N Km 4 Apartado 39 Tabernas 04200 Spain;

    Indian Inst Technol Dept Energy Sci & Engn Mumbai 400076 Maharashtra India;

    Indian Inst Technol Dept Energy Sci & Engn Mumbai 400076 Maharashtra India;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Central receiver solar thermal plant; Aerosol optical depth (AOD); AERONET; REST2; MODIS;

    机译:中央接收器太阳能热厂;气溶胶光学深度(AOD);AERONET;REST2;MODIS;