Nowadays, there is continuing worrying about energy efficiency and the reduction of GHG emissions in the building sector. It has been claimed that ventilated building envelopes help to reduce energy use in buildings and improve occupant comfort.This study proposes a comprehensive comparison of the thermal behaviour between an Opaque Ventilated Facade (OVF) and a conventional unventilated Facade (UF) considering two reference days for the winter and summer period. The analysis is developed investigating different facade orientations and two states of windiness, which are a state of calm wind and a state with wind velocity higher than zero (i.e. 5.0 m/s at 10 m of height) are taken into account.These analyses were developed utilizing fluid-dynamic calculation under dynamic conditions. Thus for the two facades were calculated: (I) the hourly surface temperatures of the most external, (II) the temperature profiles for all the facade's layers; (III) the airflow profiles inside the cavity and near the facade; (IV) the hourly thermal fluxes that cross the facade.Finally, the daily energy fluxes and the energy-saving, achievable through the adoption of the OVF, is calculated for the different facade exposures and the conditions of windiness.The outcomes of this study highlight that the OVF guarantees an energy-saving ranging from 20 to 55%, with the highest rate during the summer day for the facade facing East/West.
机译:如今,继续担心能源效率和建筑业的温室气体排放量。据称,通风建筑信封有助于减少建筑物中的能源使用,提高乘员舒适性。本研究提出了考虑到两次参考日的不透明通风外分(OVF)和传统的不通荐门面(UF)之间的热行为的全面比较冬季和夏季。调查分析调查不同的外立面向和两个蜿蜒的亮度,这是一种平静的风状态,风速高于零的状态(即,高度为5.0m / s的高度)。这些分析是在动态条件下利用流体动态计算开发。因此,对于两个外墙计算:(i)最外部的每小时表面温度,(ii)所有门面层的温度曲线; (iii)空腔内的气流型材和门面附近; (iv)通过采用OVF来实现越过外立面的每小时热量,通过采用OVF来实现每日能量助量和节能。本研究的结果,计算了不同的外立面暴露和条件。本研究的结果突出显示OVF保证从20%到55%的节能,夏季的夏季率最高,面向东部/西方的立面。

著录项

  • 来源
    《Solar Energy》 |2020年第7期|531-544|共14页
  • 作者

    Gagliano A.; Aneli S.;

  • 作者单位

    Dept Elect Elect & Informat Engn Viale Andrea Doria 6 I-95125 Catania Italy;

    Dept Elect Elect & Informat Engn Viale Andrea Doria 6 I-95125 Catania Italy;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Ventilated facade; Computational fluid dynamic; Energy saving;