首页> 外文期刊>日本建築学会環境系論文集 >2棟の実証棟での測定に基づく外壁?屋根への遮熱技術の導入効果の確認:通気層を有する外壁?屋根の遮熱?断熱効果の計算法に関する研究(その4)
【24h】

2棟の実証棟での測定に基づく外壁?屋根への遮熱技術の導入効果の確認:通気層を有する外壁?屋根の遮熱?断熱効果の計算法に関する研究(その4)

机译:基于两座示范建筑的实测,证实了将隔热技术引入外墙和屋顶的效果:带有通风层的外墙和屋顶的隔热和隔热效果的计算方法研究(第四部分)

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Indoor thermal comfort and energy consumption during summer season are greatly influenced by the radiant heat from windows as well as walls and ceilings. The objective of this report is to compare the surface temperatures of the second floor room of the two test houses, one with sunshading techniques and the other without them, and to verify the proposed calculation method by comparing calculated indoor surface temperatures with measurements. The following results were obtained.rn(1) The surface temperatures of the test house with sunshading techniques were lower than those of the test house without sunshading techniques during summer, while as the same level as them during winter.rn(2) The calculated surface temperatures well agreed with the measurements.%次世代省エネルギー基準のⅤ地域に適合するA棟,A棟の仕様にrn外表面の高反射化?通気層の放射熱伝達の低減?通気層からの排熱rn促進の遮熱技術を導入したB棟について,2階室内温熱環境の比較rnと室内表面温度の計算値と測定値の比較から,以下の知見を得た。
机译:窗户,墙壁和天花板的辐射热极大地影响了夏季的室内热舒适度和能源消耗。本报告的目的是比较两个测试室二楼房间的表面温度,其中一个带有遮阳棚。技术和其他没有它们的技术,并通过将计算出的室内表面温度与测量值进行比较来验证所提出的计算方法。获得以下结果.rn(1)采用遮阳技术的测试房屋的表面温度低于测试温度夏季没有遮阳技术的房屋,而冬季则与冬季相同。rn(2)计算得出的表面温度与测量值完全吻合。%满足下一代节能标准V区域的A栋和A栋的规格rn外表面的反射增加?减少通风层中的辐射热传递?比较B建筑物二楼的室内热环境,该建筑物引入了隔热屏技术以促进通风层rn的余热rn和室内表面温度的计算通过将测量值与测量值进行比较获得以下发现。