首页> 外文期刊>Nuclear instruments and methods in physics research >Calibration procedures of the Tore-Supra infrared endoscopes
【24h】

Calibration procedures of the Tore-Supra infrared endoscopes

机译:Tore-Supra红外内窥镜的校准程序

获取原文
获取原文并翻译 | 示例
           

摘要

Five endoscopes equipped with infrared cameras working in the medium infrared range (3-5µm) are installed on the controlled thermonuclear fusion research device Tore-Supra. These endoscopes aim at monitoring the plasma facing components surface temperature to prevent their overheating. Signals delivered by infrared cameras through endoscopes are analysed and used on the one hand through a real time feedback control loop acting on the heating systems of the plasma to decrease plasma facing components surface temperatures when necessary, on the other hand for physics studies such as determination of the incoming heat flux . To ensure these two roles a very accurate knowledge of the absolute surface temperatures is mandatory. Consequently the infrared endoscopes must be calibrated through a very careful procedure. This means determining their transmission coefficients which is a delicate operation. Methods to calibrate infrared endoscopes during the shutdown period of the Tore-Supra machine will be presented. As they do not allow determining the possible transmittances evolution during operation an in-situ method is presented. It permits the validation of the calibration performed in laboratory as well as the monitoring of their evolution during machine operation. This is possible by the use of the endoscope shutter and a dedicated plasma scenario developed to heat it. Possible improvements of this method are briefly evoked.
机译:在受控的热核聚变研究设备Tore-Supra上安装了五台配有在中红外范围(3-5µm)中工作的红外热像仪的内窥镜。这些内窥镜旨在监控面向等离子体的组件的表面温度,以防止其过热。红外摄像头通过内窥镜传递的信号,一方面通过实时反馈控制回路进行分析和使用,该回路作用在等离子体的加热系统上,以在必要时降低面对等离子体的组件的表面温度,另一方面用于物理研究,例如确定传入的热通量。为了确保这两个角色,必须对绝对表面温度有非常准确的了解。因此,红外内窥镜必须通过非常仔细的步骤进行校准。这意味着确定它们的传输系数,这是一种微妙的操作。将介绍在Tore-Supra机器关闭期间校准红外内窥镜的方法。由于它们不允许确定操作过程中可能的透射率演变,因此提出了一种原位方法。它允许验证实验室中执行的校准以及在机器运行过程中监控其演变。这可以通过使用内窥镜快门和专门开发的等离子体场景对其加热来实现。简要介绍了此方法的可能改进。

著录项

  • 来源
  • 作者单位

    CEA, IRPM, Centre de Cadarache, 13108 Saint-Paul-lez-Durance, France;

    CEA, IRPM, Centre de Cadarache, 13108 Saint-Paul-lez-Durance, France;

    CEA, IRPM, Centre de Cadarache, 13108 Saint-Paul-lez-Durance, France;

    ITER Organization, Building 72/376, CHD, Diagnostics Division - Route de Vinon sur Verdon -13115 St Paul Lez Durance, France;

    CEA, IRPM, Centre de Cadarache, 13108 Saint-Paul-lez-Durance, France;

    CEA, IRPM, Centre de Cadarache, 13108 Saint-Paul-lez-Durance, France;

    CEA, IRPM, Centre de Cadarache, 13108 Saint-Paul-lez-Durance, France;

    Aix Marseille Universite, CNRS, IUSTI - Marseille, France;

    CEA, IRPM, Centre de Cadarache, 13108 Saint-Paul-lez-Durance, France;

    CEA, IRPM, Centre de Cadarache, 13108 Saint-Paul-lez-Durance, France;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Magnetic Fusion; Tore-Supra; Infrared Endoscopes; Calibration; Shutter;

    机译:磁融合Tore-Supra;红外内窥镜校准;快门;