首页> 外文期刊>Nuclear Instruments & Methods in Physics Research >Source detection at 100 meter standoff with a time-encoded imaging system
【24h】

Source detection at 100 meter standoff with a time-encoded imaging system

机译:使用时间编码成像系统以100米对峙距离进行源探测

获取原文
获取原文并翻译 | 示例
           

摘要

We present the design, characterization, and testing of a laboratory prototype radiological search and localization system. The system, based on time-encoded imaging, uses the attenuation signature of neutrons in time, induced by the geometrical layout and motion of the system. We have demonstrated the ability to detect a ~ 1 mCi ~(252)Cf radiological source at 100 m standoff with 90% detection efficiency and 10% false positives against background in 12 min. This same detection efficiency is met at 15 s for a 40 m standoff, and 1.2 s for a 20 m standoff.
机译:我们介绍了实验室原型放射学搜索和定位系统的设计,表征和测试。该系统基于时间编码成像,使用了中子在时间上的衰减特征,这是由系统的几何布局和运动引起的。我们证明了能够在100 m距离处检测到〜1 mCi〜(252)Cf放射源的能力,在12分钟内具有90%的检测效率和10%的背景假阳性。对于40 m的对峙,在15 s时达到了相同的检测效率;对于20 m的对峙,在1.2 s时达到了相同的检测效率。