Operation of the neutral beam system of ITER for the entire ITER pulse is foreseen, with pulse lengths extending up to 1 h. Operation for such a pulse length is entirely new for neutral beam systems and the associated sub systems. This paper reviews some of the experience gained so far in the operation of the MANTIS test bed where long pulse operation of the ITER reference type of negative ion source is being studied. The three identified adverse effects of long pulse operation-reduced negative ion yield, reduced plasma grid temperature effect (see below) and increased caesium consumption-are still being studied, but some tentative explanations for each effect are given. In addition to the aforementioned effects, some operational difficulties associated with long pulses will be discussed, and some areas where caution will be needed in the future long pulse, high power operation of the ITER injectors are indicated.
机译:可以预见,整个ITER脉冲的ITER中性束系统将运行,脉冲长度延长到1 h。对于中性束系统和相关子系统,如此脉冲长度的操作是全新的。本文回顾了迄今为止在MANTIS测试台运行中获得的一些经验,在该工作台中,正在研究ITER参考类型负离子源的长脉冲运行。仍在研究长脉冲操作,降低负离子产量,降低等离子栅温度效应(见下文)和增加铯消耗这三种已确定的不利影响,但对每种影响给出了一些初步的解释。除上述效果外,还将讨论与长脉冲相关的一些操作困难,并指出在未来的长脉冲,ITER喷油器大功率运行中需要谨慎的地方。