A newly installed Lithium Granule Injector (LGI) was used to pace edge localized modes (ELM) in DIII-D. ELM pacing efficiency was studied injecting lithium granules of nominal diameter 0.3-0.9 mm, speed of 50-120 m s~(-1) and average injection rates up to 100 Hz for 0.9 mm granules and up to 700 Hz for 0.3 mm granules. The efficiency of ELM triggering was found to depend strongly on size of the injected granules, with triggering efficiency close to 100% obtained with 0.9 mm diameter granules, lower with smaller sizes, and weakly depending on granule velocity. Robust ELM pacing was demonstrated in ITER-like plasmas for the entire shot length, at ELM frequencies 3-5 times larger than the 'natural' ELM frequency observed in reference discharges. Within the range of ELM frequencies obtained, the peak ELM heat flux at the outer strike point was reduced with increasing pacing frequency. The peak heat flux reduction at the inner strike point appears to saturate at high pacing frequency. Lithium was found in the plasma core, with a concurrent reduction of metallic impurities and carbon. Overall, high frequency ELM pacing using the lithium granule injection appears to be compatible with both H-mode energy confinement and attractive H-mode pedestal characteristics, but further assessment is needed to determine whether the projected heat flux reduction required for ITER can be met.
机译:新安装的锂颗粒喷射器(LGI)用于在DIII-D中加速边缘定位模式(ELM)。研究了注射标称直径为0.3-0.9 mm的锂颗粒,速度为50-120 m s〜(-1)的锂颗粒的ELM起搏效率,以及0.9 mm颗粒的平均注射速率高达100 Hz,0.3 mm颗粒的平均注射速率高达700 Hz。发现ELM触发的效率很大程度上取决于所注射颗粒的大小,对于0.9毫米直径的颗粒,触发效率接近100%,较小的尺寸则较低,而与颗粒速度的相关性很弱。在类似ITER的等离子体中,在整个发射过程中都表现出了强大的ELM起搏,其ELM频率是参考放电中观察到的“自然” ELM频率的3-5倍。在获得的ELM频率范围内,外部起搏点的ELM峰值热通量随着起搏频率的增加而降低。内部起爆点处的峰值热通量减少似乎在高起搏频率下达到饱和。在等离子体核心中发现了锂,同时减少了金属杂质和碳。总体而言,使用锂颗粒注射剂的高频ELM起搏似乎与H模式能量限制和有吸引力的H模式基座特性兼容,但需要进一步评估以确定是否可以满足ITER所需的预计热通量降低。

著录项

  • 来源
    《Nuclear fusion》 |2016年第5期|056008.1-056008.16|共16页
  • 作者单位

    Princeton Plasma Physics Labortory, Princeton, NJ 08543, USA;

    Princeton Plasma Physics Labortory, Princeton, NJ 08543, USA;

    Princeton Plasma Physics Labortory, Princeton, NJ 08543, USA;

    Princeton Plasma Physics Labortory, Princeton, NJ 08543, USA;

    Princeton Plasma Physics Labortory, Princeton, NJ 08543, USA;

    Oak Ridge National Laboratory, Oak Ridge, TN 37831, USA;

    Oak Ridge National Laboratory, Oak Ridge, TN 37831, USA;

    General Atomics, PO Box 85608, San Diego, CA 92186, USA;

    Princeton Plasma Physics Labortory, Princeton, NJ 08543, USA;

    Princeton Plasma Physics Labortory, Princeton, NJ 08543, USA;

    General Atomics, PO Box 85608, San Diego, CA 92186, USA;

    Oak Ridge Associated Universities, Oak Ridge, TN 37831, USA;

    Princeton Plasma Physics Labortory, Princeton, NJ 08543, USA;

    General Atomics, PO Box 85608, San Diego, CA 92186, USA;

    Princeton Plasma Physics Labortory, Princeton, NJ 08543, USA;

    Lawrence Livermore National Laboratory, CA 94550, USA;

    Lawrence Livermore National Laboratory, CA 94550, USA;

    Princeton Plasma Physics Labortory, Princeton, NJ 08543, USA;

    General Atomics, PO Box 85608, San Diego, CA 92186, USA;

    Oak Ridge National Laboratory, Oak Ridge, TN 37831, USA;

    General Atomics, PO Box 85608, San Diego, CA 92186, USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    tokamak; ELM; pacing; pellet; mitigation; heat load; control;

    机译:托卡马克榆树;起搏颗粒减轻;热负荷;控制;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号