首页> 外文期刊>NDT & E international >Accurate two-dimensional modelling of piezo-composite array transducer elements
【24h】

Accurate two-dimensional modelling of piezo-composite array transducer elements

机译:压电复合阵列换能器元件的精确二维建模

获取原文
获取原文并翻译 | 示例
           

摘要

The assumption of piston-like behaviour is widely applied when modelling ultrasonic transducers. Experimental measurements of the directivity patterns of piezo-composite array transducers have shown that this assumption is not valid for small element sizes. An alternative modelling approach has been developed based on the assumption that the variation in pressure across the face of each array element can be described by a Hanning window. The effect of inter-element cross talk has been included in the model by using a window larger than the nominal size of the element. This approach has been shown to produce excellent results via validation against experiment for directivity patterns and array surface displacement. The improved modelling method has been used to quantify the errors introduced by the assumption of piston-like behaviour by comparison of modelled beam profiles generated using simple delay and sum beam forming. This has been performed by simulating a variety of different beam types and monitoring the following parameters: beam width, maximum amplitude, and beam angle. These simulations show that the only parameter significantly affected is the relative amplitude of different beam angles. The improved directivity model predicts that the maximum beam amplitude decreases with increasing beam angle at a higher rate than directivity models based on piston-like behaviour; the maximum error recorded was approximately 3 dB.
机译:在对超声换能器建模时,广泛采用了活塞式行为的假设。压电复合阵列换能器方向性图的实验测量表明,这种假设对小尺寸元件无效。基于这样的假设,已经开发出了一种替代的建模方法,该假设是,每个阵列元素表面的压力变化可以通过汉宁窗口来描述。通过使用大于元素标称尺寸的窗口,将元素间串扰的影响包括在模型中。通过针对方向性图案和阵列表面位移的实验验证,该方法已显示出出色的结果。改进的建模方法已用于通过比较使用简单延迟和求和波束形成生成的建模波束轮廓来量化由假设为活塞状行为而引入的误差。这是通过模拟各种不同的光束类型并监视以下参数来执行的:光束宽度,最大振幅和光束角度。这些模拟表明,唯一受到显着影响的参数是不同光束角的相对振幅。改进的方向性模型预测,与基于活塞式行为的方向性模型相比,最大光束幅度会随着光束角的增加而减小。记录的最大误差约为3 dB。

著录项

  • 来源
    《NDT & E international》 |2013年第6期|17-27|共11页
  • 作者单位

    Rolls-Royce Nuclear, PO BOX 2000, Derby DE21 7XX, UK,UK Research Centre for NDE, Imperial College London, Exhibition Road, London SW7 2AZ, UK;

    Rolls-Royce Nuclear, PO BOX 2000, Derby DE21 7XX, UK;

    UK Research Centre for NDE, Imperial College London, Exhibition Road, London SW7 2AZ, UK;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Phased array; Transducer; Modelling; Non-destructive evaluation;