摘要

In order to compare the role of chlorides from internal and external sources in corroding, the steel bar in concrete/ mortar, the chloride threshold level (CTL), corrosion resistance, chloride transport, observation of the steel-concrete/mortar interface and the pH-dependent release of bound chlorides were examined. As binders, ordinary Portland cement (OPC), 30% pulverised fuel ash (pfa), 60% ground granulated blastfurnace slag (ggbs) and 10% silica fume (SF) were used. For external chlorides, the onset of corrosion was detected by a jump of the galvanic current and for internal chloride the corrosion rate was measured using a polarisation technique to determine the CTL. As a result, the variation in the CTL was marginal, despite the different chloride source, but binder type greatly affected the corrosion behaviour and the CTL: OPC concretes/mortars provided the highest resistance to chloride-induced corrosion and the highest CTL, and the polarisation resistance was also the greatest before depassivation, compared to the mixtures with pozzolanic materials. For the rate of chloride transport, 60% ggbs concretes produced the lowest diffusivity, while OPC produced the highest. The visual examination of the steel-concrete interface showed that corrosion always starts in the voids in contact with the steel bar, because of a higher reactive environment. In addition, it was found that acid soluble chlorides indicate only about 90% of total.
机译:为了比较内部和外部氯化物在腐蚀,混凝土/砂浆中的钢筋,氯化物阈值水平(CTL),耐腐蚀性,氯化物传输,观察钢-混凝土/砂浆界面和pH值方面的作用检查了结合氯化物的依赖依赖性释放。作为粘合剂,使用普通的波特兰水泥(OPC),30%的粉煤灰(pfa),60%的粉状高炉矿渣(ggbs)和10%的硅粉(SF)。对于外部氯化物,通过电流的跳跃来检测腐蚀的发生,对于内部氯化物,使用极化技术测量腐蚀速率以确定CTL。结果,尽管氯化物来源不同,但CTL的变化很小,但粘结剂类型极大地影响了腐蚀行为,而CTL:OPC混凝土/砂浆提供了最高的抗氯化物腐蚀能力和最高的CTL,并且与含火山灰材料的混合物相比,钝化前的抗极化性也是最大的。就氯离子的传输速率而言,60%ggbs混凝土的扩散系数最低,而OPC的扩散系数最高。目视检查钢-混凝土界面表明,由于较高的反应环境,腐蚀总是始于与钢筋接触的空隙中。另外,发现酸溶性氯化物仅占总数的约90%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号