Numerous studies on fibre reinforced plastic (FRP) rebar-concrete bond behaviour have been carried out by many researchers. However, most of the reported works have focused on the ascending part of bond-slip behaviour, especially the maximum bond stress and corresponding slip values. Fewer efforts have been made to explore the post-peak bond-slip behaviour of FRP rebars in concrete. In this study, a series of pullout tests was performed to investigate the bond stress-slip behaviour of glass fibre reinforced plastic (GFRP) bars in concrete failed by pullout under monotonic load. The test specimens were prepared using two common types of GFRP rebars (helically wrapped and sand coated) with three different concrete strengths (25, 40 and 70 MPa). The results showed quite different pre-and post-peak bond-slip behaviours for the two GFRP types. Based on an analysis of the experimental data from this study and additional data from a literature review, simple model equations to predict the bond stress-slip behaviour for the two GFRP rebar types are suggested. The predicted bond-slip curves showed good agreement with the test results.
机译:许多研究人员已对纤维增强塑料(FRP)的钢筋混凝土粘结行为进行了大量研究。但是,大多数报道的工作都集中在粘结滑移行为的上升部分,尤其是最大粘结应力和相应的滑移值。很少有人努力研究FRP钢筋在混凝土中的峰后粘结滑移行为。在这项研究中,进行了一系列拉拔试验,以研究玻璃纤维增​​强塑料(GFRP)钢筋在混凝土中在单调荷载作用下因拉拔而失效的粘结应力-滑移行为。使用具有三种不同混凝土强度(25、40和70 MPa)的两种常见类型的GFRP钢筋(螺旋包裹和砂涂)制备试样。结果表明,两种GFRP类型的峰前和峰后粘结滑移行为截然不同。基于对本研究的实验数据和文献综述的其他数据的分析,提出了用于预测两种GFRP钢筋类型的粘结应力-滑移行为的简单模型方程。预测的粘结滑移曲线与测试结果显示出良好的一致性。

著录项

  • 来源
    《Magazine of Concrete Research》 |2012年第7期|p.575-591|共17页
  • 作者单位

    Department of Architectural Engineering,Sungkyunkwan University, Suwon, Republic of Korea;

    School of Civil, Environmental and Architectural Engineering, Korea University, Seoul, Republic of Korea;

    SK E&C Plant Business Division, Seoul,Republic of Korea;

    BK21 Division for U-City Construction,Sungkyunkwan University, Suwon, Republic of Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);