首页> 外文期刊>Magazine of Concrete Research >Flexural behaviour of externally post-tensioned two-span lightweight concrete beams
【24h】

Flexural behaviour of externally post-tensioned two-span lightweight concrete beams

机译:外柱后张力双跨度轻质混凝土梁的弯曲行为

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This study examined the effect of the partial prestressing ratio on the flexural behaviour and degree (beta) of moment redistribution of two-span lightweight aggregate concrete (LWAC) beams post-tensioned using external strands. The total length of the T-shape beam, between two exterior supports, was 10 600 mm. The unbonded prestressing three-wire strands were arranged with a harped profile of variable eccentricity, using two deviators at the sagging zone in each span and a deviator over the intermediate support. To simulate a uniform load, the top loads were uniformly distributed at four points in each span. Test results revealed that two-span externally post-tensioned LWAC beams typically exhibited smaller incremental stresses (Delta f(ps)) in the unbonded strands at the ultimate state and a smaller displacement ductility ratio than those of corresponding internally post-tensioned beams. The safety level of ACI 318-14 equations for Delta f(ps) was abruptly reduced for two-span externally post-tensioned beams, indicating non-conservative results for beams with partial prestressing ratios exceeding 0.66. The fib model code significantly overestimated the beta values of post-tensioned LWAC beams. The ACI 318-14 code also tended to overestimate the beta values of externally post-tensioned LWAC beams, although it yielded a relatively conservative estimate for externally post-tensioned LWAC beams.
机译:本研究检测了使用外部股线后张紧的双跨度轻质聚集体混凝土(LWAC)光束的弯曲行为和程度(β)的部分预应力比对使用外部股线的弯曲的弯曲行为和程度(β)的影响。在两个外部支撑件之间的T形梁的总长度为10 600mm。使用在每个跨度的下垂区的两个偏差和中间支撑件上的脱模器,使用两种偏差器布置有不合形的预应力三线股线。为了模拟均匀的负载,顶部载荷均匀地分布在每个跨度的四个点。测试结果显示,在极限状态下,在未粘附的股线中,两跨外后张紧的LWAC光束通常在未粘附的股线中表现出较小的增强(Delta F(PS)),并且比相应的内部后张紧梁的延伸延展性比较小。对于两个跨度外部后束梁,ΔF(PS)的ACI 318-14方程的安全水平突然地减小,表示具有超过0.66的部分预应力比的梁的非保守结果。 FIB模型代码显着高估了后张紧的LWAC光束的β值。 ACI 318-14代码也倾向于高估外部后张紧的LWAC光束的β值,尽管它产生了对外部后张紧的LWAC光束的相对保守的估计。

著录项

  • 来源
    《Magazine of Concrete Research》 |2019年第22期|1193-1203|共11页
  • 作者

    Mun Ju-Hyun; Yang Keun-Hyeok;

  • 作者单位

    Kyonggi Univ Architectural Engn Suwon South Korea;

    Kyonggi Univ Architectural Engn Suwon South Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF