The coulometric titration technique was developed for determination of sulfur dioxide in food and beverages. Sulfur dioxide, which presented in food and beverages in the form of bisulfite and sulfite, reacts with iodine generated from iodide at working electrode. An optimum condition for iodine generation was 10 mA of electric current in 0.1 M KI solution. The amount of sulfur dioxide in the samples could be obtained by direct calculation from the quantity of electric current used in titration or from a generation time of iodine in reaction. The whole process of sulfur dioxide detection by this technique took only 1 - 3 minutes, whereas the A.O.A.C. method using distillation and titration processes took more than 1 hour. The accuracy and precision of the modified technique for sulfur dioxide detection in food and beverages were high and comparable to the A.O.A.C. method (p<0.05) at the concentration of sulfur dioxide between 0 - 350 ppm.
机译:库仑滴定技术用于测定食品和饮料中的二氧化硫。在食品和饮料中以亚硫酸氢盐和亚硫酸盐形式存在的二氧化硫在工作电极上与由碘化物产生的碘发生反应。碘生成的最佳条件是在0.1 M KI溶液中的电流为10 mA。样品中的二氧化硫含量可以通过滴定中使用的电流量或反应中碘的生成时间直接计算得出。用这种技术检测二氧化硫的整个过程仅需1-3分钟,而A.O.A.C.使用蒸馏和滴定法的方法花费了1个多小时。用于食品和饮料中二氧化硫检测的改良技术的准确性和精密度很高,可与A.O.A.C.方法(p <0.05)在二氧化硫浓度介于0-350 ppm之间。